My understanding is that the chimney should be at least 2 feet higher than any part of the roof within 10 feet of the chimney.
How far should a c pipe be from roof.
In canada the national plumbing code requires that the minimum trap arm be at least 2 times the pipe diameter e g 1 25 inch pipe needs a 2 5 inch trap arm 1 5 pipe needs a 3 inch trap arm etc and that the vent pipe be one size larger than the drain that it serves also a cleanout is required on both the vent and the drain.
In your situation the minimum height of your chimney above the eaves should be the following depending on your roof pitch.
The vent opening must be far enough above the roof and away from doors and windows to prevent the sewer gases from drifting into the house.
Obviously look to take out the palm trees to the west as well.
They give added support to the roof and also provide a nailing surface for the end panels and drip edge.
Additionally the vent runs up the wall just outside the back door so the vent is also within 3m of the door.
They are installed on top of the roof rafters with a felt underlayment or vapor barrier installed on top.
The top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak.
First you ll need to know the pitch of your roof.
Metal roof purlins are installed horizontally under metal roofs.
Open vent pipes that extend through a roof shall be terminated at least 6 inches 152 mm above the roof or 6 inches 152 mm above the anticipated snow accumulation whichever is greater except that where a roof is to be used for any purpose other than weather protection the vent extension shall.
Roof pitch is easily calculated and if you don t know how read my article understanding and calculating roof pitch.
Does anyone know what legal height requirements there are for vent pipes or as long as it sticks out of the roof its all sweet.
Also you ll need the horizontal distance between the peak and the edge of the high side of the pipe see figure 1 where you plan your roof penetration.
Purlins are 2 by 4 feet and are installed much like metal roofing.
6 12 minimum chimney height.
I didn t know it was relevant but the vent is exiting the roof just about 400 mm from a gutter.
8 12 minimum chimney height.
I figured i could shorten the vent pipe and maybe leave a panel out directly south of the pipe and enough room on the sides so the shadow does not hit any of the panels.
The code requires a 10 foot horizontal distance from any.
If the pipe is farther than 10 feet from the roof.