They intend to make sure that the chimney draws properly and that a fire hazard does not occur.
How high chimney above roof.
And at least 2 higher than any portion of a building within 10.
This is a bit of an odd measurement and chimney clearance case because the chimney side is actually about 8 away from the roof edge.
The 10 foot rule explains the clearance you need.
Explained the chimney pipe must be a minimum of three feet above the roof but also two feet taller than anything within ten feet.
A chimney should be at least two feet above the highest roof point.
For most small structures like small cabins and tiny homes the tallest part of the structure is within 10 of the chimney.
Minimum three feet above the high side of the roof at least two feet taller than anything within ten feet.
Specifications aren t there to merely cause you problems.
There are strict codes that govern chimney placement for fire safety reasons.
It means any pipe penetrating a roof must be three feet above the roof line on the up slope side of the penetration.
Flues need to be 600mm higher than the highest part of the roof within 3 metres.
The chimney opening above the roof of a sticks and bricks house should be 3 feet above the roof line or 2 feet above any part of the building within 10 whichever is higher.
Both above the flat roof and 2 feet above the point at which a horizontal line from the chimney would touch the highest portion of the nearest roof.
This rule refers to the proper height of the chimney pipe above the roof.
The top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak.
Most wood stove and factory built fireplace manufacturers and local building codes will require that the chimney must extend at least 2 feet above any portion of any structure within 10 feet measured horizontally and must extend at least 3 feet above the highest point of its roof penetration.
The chimney must extend at least 3 above the highest point where it passes through a roof.
If there is a steep roof or nearby obstruction the chimney will need more length above the roof to meet code.
If the pipe is farther than 10 feet from the roof peak it must be 2.